INSTALLATION AND OPERATION MANUAL
DAVEY SPA BATH PUMP
C200A, C270A, C400A
C200AB, C270AB, C400AB
C200TB, C270TB, C400TB
– 2 –
Your Davey Spa Bath Pump
Congratulations on your purchase of a quality product from the Davey
range of Pool and Spa Equipment. You are assured of many years of
reliable and efcient performance from your Davey Spa Bath Pump backed
by Davey’s two year guarantee.
The Davey Spa Bath Pump range has been specially designed to offer
optimum performance and ample bubbling pressure in spa baths. It should
not be used for any other purpose without rst consulting your Davey
Dealer or Davey Customer Service Centre.
The AB and TB models incorporate a thermostatically controlled heater
element. The heater element maintains the bath water temperature for a
long hot bath.
The Celsior range is designed for use in spa baths. They are not
recommended for use in chemically treated spa pool water.
At Davey we design and build our own electric motors especially for our
pumps. The matched motor and “pumping end” are designed to provide
quiet operation while delivering optimum water ow.
Davey’s totally enclosed motor incorporates “auto-start” overload protection
with a built-in automatic thermostat designed to protect the motor from
overheating. The excess heat from the motor is captured by the spa water,
ensuring a long hot soak.
Davey Spa Bath Pumps are constructed of durable thermoplastic,
eliminating corrosion problems and consequent spa bath staining. Specially
designed to be self-draining (when installed as per instructions), the pump
drains after use, preventing the build-up of stale water.
Installation and Operating Instructions
Location
The pump should be located as close to the spa bath as practicable (either
internally or externally). It is the installer’s/owner’s responsibility to locate
the pump such that the nameplate can be easily read and it can be readily
accessed for service.
It is recommended that the pump is protected from the weather. Enclosures
should be ventilated to prevent condensation build–up.
Failure to adequately install the Spa Bath Pump as outlined above may
result in pump damage and/or removal costs not covered by the guarantee.
– 3 –
Electrical Connection
In the interests of safety, we advise that all Spa Bath Pumps must be
installed in accordance with relevant standards, particularly AS 3000 wiring
rules or equivalent.
This product is suitable for connection to a nominal 240V 50Hz power
supply and is equipped with a lead and three pin plug.
This product must be installed so the motor can be turned off independently
of the air button or touch pad (a standard ON/OFF power point provides
this).
If the supply cord of this product is damaged it must be replaced with a
genuine Davey Spare Part, by the manufacturer or its service agent or a
similar qualied person in order to avoid a hazard.
Air Switch Models - Tube Connection
These pumps are supplied with an air switch tube connected to the back of
the motor on the 200, 270 & 400.
1. Before installing, ensure that :
- the tube is properly connected to the pump,
- the tube can be connected to the air button (not supplied) at the bath.
2. When installing route the tube via the shortest possible path to the air
button. Ensure that there are no kinks.
3. Do not loop air tube around pipe work or framing.
Electronic Models - Touchpad Assembly / Installation
These models are supplied with a low voltage electronic touch pad to
control pump and heater functions.
Assembly
Click faceplate onto touch pad. Then apply label to faceplate/touchpad
assembly ensuring it is right way up.
Installation
The assembled touchpad is then ready for mounting at the bath. Route
the lead to enable connection at both the touchpad and pump ends. A
26mm dia. hole is required to mount the touchpad ush on the bath surface
(usually pre drilled by bath manufacturer).
Apply a bead of silicone on the touchpad box only to secure it to the bath
surface and prevent water leaking under the bath. Do not silicone the clip
on faceplate to the bath surface.
IMPORTANT INSTALLATION INFORMATION
(Pump must be able to self drain)
Please pass these instructions on to the owner of this equipment.
PUMP POSITION IS IMPORTANT
PLUMBERS NOTE!
NOTE: To avoid possible water damage to property from ruptured
pipes, leaking connections, worn/leaking pump seals, etc., pumps
must be installed on a well drained site or in a properly construct-
ed drain tray.
CELSIOR
HEAT RECOVERY
TM
Warning! Ensure that an electrical isolation switch is located
with easy access so that the pump can be switched off in an
emergency.
Davey
®
Repair or Replacement Guarantee
In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction
within two years of the date of original purchase due to faulty materials or manufacture, Davey will at
our option repair or replace it for you free of charge, subject to the conditions below.
Should you experience any difculties with your Davey product, we suggest in the rst instance that
you contact the Davey Dealer from which you purchased the Davey product. Alternatively you can
phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or
send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to
resolve your difculties or, if the product is faulty or defective, advise you on how to have your Davey
product repaired, obtain a replacement or a refund.
Your Davey Two Year Guarantee naturally does not cover normal wear or tear, replacement of product
consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from misuse
or negligent handling, improper use for which the product was not designed or advertised, failure to
properly follow the provided installation and operating instructions, failure to carry out maintenance,
corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons
attempting repairs. Where applicable, your Davey product must only be connected to the voltage
shown on the nameplate.
Your Davey Two Year Guarantee does not cover freight or any other costs incurred in making a claim.
Please retain your receipt as proof of purchase; you MUST provide evidence of the date of original
purchase when claiming under the Davey Two Year Guarantee.
Davey shall not be liable for any loss of prots or any consequential, indirect or special loss, damage
or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation
does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to
your Davey product under the Australian or New Zealand legislation and does not affect any rights or
remedies that may be available to you under the Australian or New Zealand Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation for
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major
failure.
Should your Davey product require repair or service after the guarantee period; contact your nearest
Davey Dealer or phone the Davey Customer Service Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:
* Installation and operating instructions are included with the product when purchased new.
They may also be found on our website.
P/N 49375-8 supersedes P/N 49375-7
AUSTRALIA
Customer Service Centre
6 Lakeview Drive,
Scoresby, Australia 3179
Ph: 1300 367 866
Fax: 1300 369 119
Website: davey.com.au
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
NEW ZEALAND
Customer Service Centre
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph: 0800 654 333
Fax: 09 527 7654
Website: daveynz.co.nz
® Davey is a registered trade mark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2011.
Page view 0
1 2

Summary of Contents

Page 1 - HEAT RECOVERY

INSTALLATION AND OPERATION MANUALDAVEY SPA BATH PUMPC200A, C270A, C400AC200AB, C270AB, C400ABC200TB, C270TB, C400TB– 2 –Your Davey Spa Bath PumpCongra

Page 2 - Activating Air Bleed

– 7 –– 4 –Plumbing InstallationThis product is supplied with barrel unions which accept 40mm PVC pipe.In all cases, the pump must be installed so that

Comments to this Manuals

No comments